Early Detection of Ventilator-associated Pneumonia From Exhaled Breath in Intensive Care Unit Patients
Umer Bakali1, Chitvan Killawala1,2, Evelise Monteagudo1
1Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL.
Objective:
Evaluate associations between volatile organic compounds (VOCs) in heat and moisture exchange (HME) filters and the presence of ventilator-associated pneumonia (VAP).
Background:
Clinical diagnostic criteria for VAP have poor interobserver reliability, and cultures are slow to result. Exhaled breath contains VOCs related to gram-negative bacterial proliferation, the most identified organisms in VAP. We hypothesized that exhaled VOCs on HME filters can predict nascent VAP in mechanically ventilated intensive care unit patients.
Methods:
Gas chromatography-mass spectrometry was used to analyze 111 HME filters from 12 intubated patients who developed VAP. Identities and relative amounts of VOCs were associated with dates of clinical suspicion and culture confirmation of VAP. Matched pairs t tests were performed to compare VOC abundances in HME filters collected within 3 days pre and postclinical suspicion of VAP (pneumonia days), versus outside of these days (non-pneumonia days). A receiver operating characteristic curve was generated to determine the diagnostic potential of VOCs.
Results:
Carbon disulfide, associated with the proliferation of certain gram-negative bacteria, was found in samples collected during pneumonia days for 11 of 12 patients. Carbon disulfide levels were significantly greater ( P = 0.0163) for filters on pneumonia days. The Area Under the Curve of the Reciever Operating Characteristic curve (AUC ROC) for carbon disulfide was 0.649 (95% CI: 0.419-0.88).
Conclusions:
Carbon disulfide associated with gram-negative VAP can be identified on HME filters up to 3 days before the initial clinical suspicion, and approximately a week before culture confirmation. This suggests VOC sensors may have potential as an adjunctive method for early detection of VAP.
Related Concept Videos
Pneumonia III: Complications and Assessment
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...