Agreement between Vital Signs Measured Using Mat-Type Noncontact Sensors and Those from Conventional Clinical
Daiki Shimotori1, Eri Otaka1, Kenji Sato2
1Laboratory of Practical Technology in Community, Assistive Robot Center, National Center for Geriatrics and Gerontology, Obu 474-8511, Aichi, Japan.
Abstract:
Vital signs are crucial for assessing the condition of a patient and detecting early symptom deterioration. Noncontact sensor technology has been developed to take vital measurements with minimal burden. This study evaluated the accuracy of a mat-type noncontact sensor in measuring respiratory and pulse rates in patients with cardiovascular diseases compared to conventional methods. Forty-eight hospitalized patients were included; a mat-type sensor was used to measure their respiratory and pulse rates during bed rest. Differences between mat-type sensors and conventional methods were assessed using the Bland-Altman analysis. The mean difference in respiratory rate was 1.9 breaths/min (limits of agreement (LOA): -4.5 to 8.3 breaths/min), and proportional bias existed with significance (r = 0.63, p < 0.05). For pulse rate, the mean difference was -2.0 beats/min (LOA: -23.0 to 19.0 beats/min) when compared to blood pressure devices and 0.01 beats/min (LOA: -11.4 to 11.4 beats/min) when compared to 24-h Holter electrocardiography. The proportional bias was significant for both comparisons (r = 0.49, p < 0.05; r = 0.52, p < 0.05). These were considered clinically acceptable because there was no tendency to misjudge abnormal values as normal. The mat-type noncontact sensor demonstrated sufficient accuracy to serve as an alternative to conventional assessments, providing long-term monitoring of vital signs in clinical settings.
Related Concept Videos
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: