On the Maximum Obtainable Purity and Resultant Maximum Useful Membrane Selectivity of a Membrane Separator
Sean-Thomas B Lundin1, Ayumi Ikeda1, Yasuhisa Hasegawa1
1Research Institute of Chemical Process Technology, National Institute of Advanced Industrial Science and Technology (AIST), 4-2-1 Nigatake, Miyagino-ku, Sendai 983-8551, Japan.
Abstract:
Design considerations concerning the maximum purity of a membrane separator, and the resultant maximum effective selectivity of the membranes were explored by modeling a binary gas membrane separator (pressure-driven permeance) using a dimensionless form. Although the maximum purity has an analytical solution at the limit of zero recovery or stage cut, this solution over-predicts the obtained purity as the recovery is increased. Furthermore, at combinations of high recovery, low feed mole fraction, and low pressure ratio, the maximum purity becomes independent of selectivity above some critical selectivity. As a consequence of this purity limitation, a maximum selectivity is defined at which further increases in selectivity will result in less than a 1% change in the final purity. An equation is obtained that specifies the region in which a limiting purity is less than unity (indicating the existence of a limiting selectivity); operating at less than the limiting pressure ratio results in a purity limitation less than unity. This regime becomes larger and more significant as the inlet mole fraction decreases (e.g., inlet feed mole fraction of 10% and pressure ratio of 100 results in a maximum useful membrane selectivity of only 130 at 95% recovery). These results suggest that membrane research should focus on increasing permeance rather than selectivity for low-concentration separations. The results found herein can be used to set benchmarks for membrane development in various gas separation applications.
Related Concept Videos
Detergent Purification of Membrane Proteins
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Osmosis and Osmotic Pressure of Solutions
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Dialysis