Related Experiment Video
Updated: Jun 22, 2025

High Resolution Physical Characterization of Single Metallic Nanoparticles
Published on: June 28, 2019
Predictive modeling of pH on the transport of Co(II) Ions from aqueous solutions through supported ceramic polymer
A T Kassem1, M M S Ali1, N M Sami2
1Hot Laboratories and Waste Management Center, Egyptian Atomic Energy Authority, Cairo, 13759, Egypt.
Abstract:
Optimal pH is essential for efficient cobalt extraction from polymeric membrane systems, with D2EHPA used as an extractant for Co(II) at pH < 7, achieving 47% efficiency. The pH of piperazine as a stripping agent increases to a concentration of 0.48 M, and the extraction efficiency of Co(II) > 80%. Depending on the functional group of (C4H10N2), the optimal pH for separation was 9.8. The study revealed that pKa value was calculated to predict the ideal pH, and its value was 9.73, which is nearly to the pH, since the pH of the strip concentration and the properties of the membrane affect the extraction of cobalt at 30 °C. The partition ratio indicates the high distribution of the extract in supported ceramic polymer membrane (SCPM). The ceramic component provides mechanical strength and rigidity to the overall membrane structure, allowing it to withstand high pressures and temperatures during operation Study various factors such as the effect of pH on the ionization of the extract; effect of pH on band ionization; effect of pH on the temperature in the extract, effect of pH on the solute, effect of the band at different pH ranges and a comparison was made between the predictive model and experimental data that was proven through mathematical modeling using the MATLAB program.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
08:03Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
Published on: April 18, 2013
Related Concept Videos
Potentiometry: Membrane Electrodes
Extraction: Effects of pH
Extraction: Advanced Methods
Factors Affecting Solubility
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...