Related Experiment Video
Updated: Jun 22, 2025

Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Optimization of Liquid Crystalline Mixtures Enantioseparation on Polysaccharide-Based Chiral Stationary Phases by
1Institute of Chemistry, Military University of Technology, ul. Sylwestra Kaliskiego 2, 00-908 Warsaw, Poland.
Abstract:
Enantioseparation of nineteen liquid crystalline racemic mixtures obtained based on (R,S)-2-octanol was studied in reversed-phase mode on an amylose tris(3-chloro-5-methylphenylcarbamate) (ReproSil Chiral-MIG) and a cellulose tris(3,5-dichlorophenylcarbamate) (ReproSil Chiral-MIC). These polysaccharide-based chiral stationary phase (CSP) columns for High-Performance Liquid Chromatography (HPLC) were highly effective in recognizing isomers of minor structural differences. The mobile phase (MP), which consists of acetonitrile (ACN)/water (H2O) at different volume ratios, was used. The mobile phases were pumped at a flow rate of 0.3, 0.5, or 1 mL·min-1 with a column temperature of 25 °C, using a UV detector at 254 nm. The order of the elution was also determined. The chromatographic parameters, such as resolution (Rs), selectivity (α), and the number of theoretical plates, i.e., column efficiency (N), were determined. The polysaccharide-based CSP columns have unique advantages in separation technology, and this study has shown the potential usefulness of the CSP columns in separating liquid crystalline racemic mixtures belonging to the same homologous series.
More Related Videos
09:14Enzymatic Cascade Reactions for the Synthesis of Chiral Amino Alcohols from L-lysine
Published on: February 16, 2018
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Racemic Mixtures and the Resolution of Enantiomers
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...