Related Experiment Video
Updated: Jun 22, 2025

Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
Evaluation of Multiple RNA Extraction Protocols for Chikungunya Virus Screening in Aedes aegypti Mosquitoes
Bárbara Caroline Garcia Freitas1,2, Daniel Damous Dias1,2, Lúcia Aline Moura Reis1,2
1Parasite Biology in the Amazon Region Graduate Program, Pará State University, Belém 66087-670, PA, Brazil.
Abstract:
Chikungunya virus (Togaviridae, Alphavirus; CHIKV) is a mosquito-borne global health threat. The main urban vector of CHIKV is the Aedes aegypti mosquito, which is found throughout Brazil. Therefore, it is important to carry out laboratory tests to assist in the virus's diagnosis and surveillance. Most molecular biology methodologies use nucleic acid extraction as the first step and require quality RNA for their execution. In this context, four RNA extraction protocols were evaluated in Ae. aegypti experimentally infected with CHIKV. Six pools were tested in triplicates (n = 18), each containing 1, 5, 10, 20, 30, or 40 mosquitoes per pool (72 tests). Four commercial kits were compared: QIAamp®, Maxwell®, PureLink®, and PureLink® with TRIzol®. The QIAamp® and PureLink® with TRIzol® kits had greater sensitivity. Two negative correlations were observed: as the number of mosquitoes per pool increases, the Ct value decreases, with a higher viral load. Significant differences were found when comparing the purity and concentration of RNA. The QIAamp® protocol performed better when it came to lower Ct values and higher RNA purity and concentration. These results may provide help in CHIKV entomovirological surveillance planning.