Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Blood Transfusion01:15

Blood Transfusion

Blood transfusion is a critical medical procedure that saves lives and treats various medical conditions. It involves transferring blood from a donor to a recipient. This process requires a thorough understanding of the ABO blood group system and its associated antigens and antibodies.
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Nanowrinkled Interface-Coupled Metaphase Chromosome Spreading and Nanoscale Conformability.

ACS nano·2026
Same author

Development of a Loop-Mediated Isothermal Amplification (LAMP) for the screening of Candida auris.

PloS one·2026
Same author

Quantitative and visual evaluation of dynamic isotropy in dual-axis random positioning machine (RPM) or clinostat for ground-based microgravity simulation.

Biomedical engineering letters·2026
Same author

Tunable Wetting and Chemical Coating-Free Slip on Wrinkled PDMS for Droplet Microfluidics.

ACS polymers Au·2026
Same author

Development of a LAMP assay using hybridization-based TaqMan-style probes (HyTaq) for simultaneous detection of wild-type and macrolide-resistant <i>Mycoplasma pneumoniae</i>.

Journal of clinical microbiology·2025
Same author

Needle-free, Liquid Metal-embedded Electrospray Deposition System for Controlled Microdroplet Printing.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2025

Related Experiment Video

Updated: Jun 19, 2026

Adaptation of Semiautomated Circulating Tumor Cell CTC Assays for Clinical and Preclinical Research Applications
14:14

Adaptation of Semiautomated Circulating Tumor Cell CTC Assays for Clinical and Preclinical Research Applications

Published on: February 28, 2014

15.9K

Evaluation of Pre-Transfusion Crossmatch Test Using Microscanner C3.

Insu Park1, Woong Sik Jang2, Chae Seung Lim3,4

  • 1BK21 Graduate Program, Department of Biomedical Sciences, College of Medicine, Korea University, Seoul 02841, Republic of Korea.

Diagnostics (Basel, Switzerland)
|June 27, 2024
PubMed
Summary

A new Microscanner C3 blood crossmatch test shows high accuracy for pre-transfusion compatibility testing. This automated method offers a reliable alternative to traditional tests, improving patient safety and blood product management.

Keywords:
blood bankcrossmatchmicroscannerpre-transfusiontransfusion

More Related Videos

Routine Screening Method for Microparticles in Platelet Transfusions
09:49

Routine Screening Method for Microparticles in Platelet Transfusions

Published on: January 31, 2018

15.9K
Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
05:58

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes

Published on: March 22, 2022

4.0K

Related Experiment Videos

Last Updated: Jun 19, 2026

Adaptation of Semiautomated Circulating Tumor Cell CTC Assays for Clinical and Preclinical Research Applications
14:14

Adaptation of Semiautomated Circulating Tumor Cell CTC Assays for Clinical and Preclinical Research Applications

Published on: February 28, 2014

15.9K
Routine Screening Method for Microparticles in Platelet Transfusions
09:49

Routine Screening Method for Microparticles in Platelet Transfusions

Published on: January 31, 2018

15.9K
Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
05:58

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes

Published on: March 22, 2022

4.0K

Area of Science:

  • Transfusion Medicine
  • Clinical Pathology
  • Medical Device Technology

Background:

  • Pre-transfusion crossmatch testing is essential for blood transfusion safety.
  • Conventional tube methods present challenges such as subjective interpretation and human error.
  • There is a need for more accurate and standardized crossmatching techniques.

Purpose of the Study:

  • To evaluate the diagnostic performance of a novel crossmatch test utilizing Microscanner C3.
  • To compare the Microscanner C3 method against conventional crossmatching techniques.
  • To assess the potential of Microscanner C3 to enhance automation and accuracy in pre-transfusion testing.

Main Methods:

  • A new crossmatch test employing the Microscanner C3 system was developed.
  • The diagnostic performance was assessed using 323 clinical blood samples.
  • Key performance metrics including sensitivity, specificity, and concordance rates were calculated.

Main Results:

  • The Microscanner C3 crossmatch test demonstrated high sensitivity (98.20%) and perfect specificity (100.00%).
  • Positive and negative predictive values were notably high at 100.00% and 98.11%, respectively.
  • A high concordance rate of 99.07% was observed, indicating excellent agreement with established methods.

Conclusions:

  • The Microscanner C3 system provides a promising and accurate alternative for pre-transfusion crossmatch testing.
  • This method offers improvements in automation, standardization, and reliability over conventional tube methods.
  • Adoption of Microscanner C3 can enhance efficiency, patient safety, and optimize blood product utilization.