Related Experiment Video
Updated: May 4, 2026

Surgical Retrieval, Isolation and In vitro Expansion of Human Anterior Cruciate Ligament-derived Cells for Tissue Engineering Applications
Published on: April 30, 2014
Prediction of the Hamstring Graft Size for ACL Reconstruction Using Different Axial Layers in Preoperative MRI
Moritz Florian Mayr1, Markus Siegel1, Elham Taghizadeh2
1Department of Orthopedic Surgery and Traumatology, Freiburg University Hospital, Albert Ludwigs University Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany.
Background:
In ACL reconstruction, it is desirable to assess preoperatively whether a sufficient graft diameter can be achieved with the planned tendon graft. The present study investigated the effect of the location of the cross-sectional area (CSA) measurement of the hamstring tendons in preoperative MRI on the correlation of the CSA with the intraoperative graft diameter. In addition, we analyzed whether the measurement results of examiners with different skill levels were comparable.
Methods:
A total of 32 subjects undergoing a single bundle ACL reconstruction using an autologous ipsilateral quadrupled hamstring graft (STGT) were included. The CSA of the semitendinosus and gracilis tendon was determined in preoperative MRI on six defined levels by three examiners. The intraclass correlation coefficient between the measurements of these observers was determined. The correlation between the sum of the CSA of both tendons (CSA STGT) and the graft diameter was investigated.
Results:
The interrater reliability was excellent on most of the investigated levels. A significant correlation between CSA STGT and the graft diameter was seen on all levels. The strongest correlation was found on the level 10 mm above the joint line.
Conclusions:
The measurement of the CSA STGT in the preoperative MRI 10 mm above the joint line enabled a good assessment of the achievable graft diameter in ACL reconstruction, independent of the examiners' training level.