Related Experiment Video
Updated: Jun 22, 2025

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Pulse Design of Constant Strain Rate Loading in SHPB Based on Pulse Shaping Technique
Shengpeng Chen1, Runqiang Chi1, Wuxiong Cao1
1School of Astronautics, Harbin Institute of Technology, Harbin 150001, China.
Abstract:
The Split Hopkinson pressure bar (SHPB) is widely used for characterizing the mechanical behavior of materials at high strain rates. One of the most challenging factors is achieving constant strain rate (CSR) loading of the specimen at a certain strain rate. Obtaining the effective incident pulse based on the experimental material for achieving CSR loading remains unresolved. This research focuses on obtaining the proper incident pulse for achieving constant strain rate loading using the pulse-shaping technique. A parameterized objective incident model in terms of the strain rate and quasi-static (or dynamic stress-strain) behavior of the material is established utilizing the three-wave method. Experimental pulses that closely resemble the desired objective pulses can be generated by adjusting parameters such as the geometry of the shaper, the shaper material, striker velocities, and the length of the striker according to the pulse-shaping model. The model is applied to the design of the incident pulse for B4CP/2024Al composite material, and the dynamic stress-strain curves at different strain rates are obtained under CSRs. This model provides effective guidance for selecting an appropriate shaper and achieving CSR loading in SHPB tests.
Related Concept Videos
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...
Elastic Strain Energy for Shearing Stresses
Voltammetric Techniques: Pulse Voltammetry

