A Guide to Measuring Heart and Respiratory Rates Based on Off-the-Shelf Photoplethysmographic Hardware and
Guylian Stevens1, Luc Hantson2, Michiel Larmuseau3
1Department of Electronics and Information Systems-IBiTech, Korneel Heymanslaan, Ghent University, 9000 Ghent, Belgium.
Abstract:
The remote monitoring of vital signs via wearable devices holds significant potential for alleviating the strain on hospital resources and elder-care facilities. Among the various techniques available, photoplethysmography stands out as particularly promising for assessing vital signs such as heart rate, respiratory rate, oxygen saturation, and blood pressure. Despite the efficacy of this method, many commercially available wearables, bearing Conformité Européenne marks and the approval of the Food and Drug Administration, are often integrated within proprietary, closed data ecosystems and are very expensive. In an effort to democratize access to affordable wearable devices, our research endeavored to develop an open-source photoplethysmographic sensor utilizing off-the-shelf hardware and open-source software components. The primary aim of this investigation was to ascertain whether the combination of off-the-shelf hardware components and open-source software yielded vital-sign measurements (specifically heart rate and respiratory rate) comparable to those obtained from more expensive, commercially endorsed medical devices. Conducted as a prospective, single-center study, the research involved the assessment of fifteen participants for three minutes in four distinct positions, supine, seated, standing, and walking in place. The sensor consisted of four PulseSensors measuring photoplethysmographic signals with green light in reflection mode. Subsequent signal processing utilized various open-source Python packages. The heart rate assessment involved the comparison of three distinct methodologies, while the respiratory rate analysis entailed the evaluation of fifteen different algorithmic combinations. For one-minute average heart rates' determination, the Neurokit process pipeline achieved the best results in a seated position with a Spearman's coefficient of 0.9 and a mean difference of 0.59 BPM. For the respiratory rate, the combined utilization of Neurokit and Charlton algorithms yielded the most favorable outcomes with a Spearman's coefficient of 0.82 and a mean difference of 1.90 BrPM. This research found that off-the-shelf components are able to produce comparable results for heart and respiratory rates to those of commercial and approved medical wearables.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...