Related Experiment Video
Updated: Jul 18, 2026

Determining 3D Flow Fields via Multi-camera Light Field Imaging
Published on: March 6, 2013
Probability-Based LIDAR-Camera Calibration Considering Target Positions and Parameter Evaluation Using a Data Fusion
Ryuhei Yamada1, Yuichi Yaguchi1
1Department of Computer Science and Engineering, The University of Aizu, Tsuruga, Ikki-Machi, Aizu-Wakamatsu 965-8580, Fukushima, Japan.
Abstract:
The data fusion of a 3-D light detection and ranging (LIDAR) point cloud and a camera image during the creation of a 3-D map is important because it enables more efficient object classification by autonomous mobile robots and facilitates the construction of a fine 3-D model. The principle behind data fusion is the accurate estimation of the LIDAR-camera's external parameters through extrinsic calibration. Although several studies have proposed the use of multiple calibration targets or poses for precise extrinsic calibration, no study has clearly defined the relationship between the target positions and the data fusion accuracy. Here, we strictly investigated the effects of the deployment of calibration targets on data fusion and proposed the key factors to consider in the deployment of the targets in extrinsic calibration. Thereafter, we applied a probability method to perform a global and robust sampling of the camera external parameters. Subsequently, we proposed an evaluation method for the parameters, which utilizes the color ratio of the 3-D colored point cloud map. The derived probability density confirmed the good performance of the deployment method in estimating the camera external parameters. Additionally, the evaluation quantitatively confirmed the effectiveness of our deployments of the calibration targets in achieving high-accuracy data fusion compared with the results obtained using the previous methods.
More Related Videos
12:34Methods for Measuring the Orientation and Rotation Rate of 3D-printed Particles in Turbulence
Published on: June 24, 2016
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Vector Functions and Motion: Problem Solving