Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

573
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
573

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Long-Term Stable Biosensing Using Multiscale Biostructure-Preserving Metal Thin Films.

Biosensors·2026
Same author

Ultrasound-guided supraclavicular internal jugular vein compression to increase internal jugular vein cross-sectional area in hospitalized patients: a prospective observational study in Japan.

Acute and critical care·2025
Same author

Porphyran from discolored nori prevents metabolic syndrome through microbiota-bile acid-ceramide pathway.

iScience·2025
Same author

Molecular Shape-Preserving Au Electrode for Progesterone Detection.

Sensors (Basel, Switzerland)·2025
Same author

Association between patient position-induced breast shape changes on prone and supine MRI and mammographic breast density or thickness.

Japanese journal of radiology·2024
Same author

The effects of bolus isosorbide dinitrate on pulmonary hypertension with cardiopulmonary comorbidities.

Heart and vessels·2024

Related Experiment Video

Updated: Jun 22, 2025

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

6.7K

Ultra-High Vacuum Cells Realized by Miniature Ion Pump Using High-Efficiency Plasma Source.

Yuichi Kurashima1, Atsuhiko Maeda1, Naoto Oshima2

  • 1Device Technology Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8564, Japan.

Sensors (Basel, Switzerland)
|June 27, 2024
PubMed
Summary
This summary is machine-generated.

Researchers developed an ultra-high vacuum miniature cell using a compact ion pump. This breakthrough enables the miniaturization of quantum devices, paving the way for advanced quantum technologies.

Keywords:
cold atomminiature ion pumppenning vacuum gaugeultra-high vacuum cell

More Related Videos

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

12.6K
Cryogenic Liquid Jets for High Repetition Rate Discovery Science
08:34

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

Published on: May 9, 2020

3.0K

Related Experiment Videos

Last Updated: Jun 22, 2025

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

6.7K
Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

12.6K
Cryogenic Liquid Jets for High Repetition Rate Discovery Science
08:34

Cryogenic Liquid Jets for High Repetition Rate Discovery Science

Published on: May 9, 2020

3.0K

Area of Science:

  • Quantum Technology
  • Vacuum Science
  • Materials Science

Background:

  • Quantum technology relies on miniaturized devices.
  • Miniaturization requires ultra-high vacuum (UHV) conditions, typically below 10-6 Pa.
  • Existing UHV solutions are often bulky and unsuitable for miniature devices.

Purpose of the Study:

  • To develop a UHV miniature cell for quantum devices.
  • To integrate a miniature ion pump for vacuum generation.
  • To demonstrate the feasibility of UHV in a sealed miniature cell.

Main Methods:

  • Fabrication of a miniature vacuum cell incorporating a miniature ion pump.
  • Introduction of the unsealed pump into a vacuum chamber for evaluation.
  • Measurement of the ion pump's discharge current to assess vacuum pressure.
  • Hermetic sealing of the miniature pump within the cell.
  • Evacuation of the sealed cell to UHV using the integrated miniature ion pump.

Main Results:

  • Successful integration of a miniature ion pump into a vacuum cell.
  • Demonstrated correlation between ion pump discharge current and vacuum pressure.
  • Achieved UHV conditions within the sealed miniature cell, verified by discharge current measurements.
  • Confirmed the feasibility of the developed cell for UHV requirements.

Conclusions:

  • The developed miniature UHV cell is suitable for miniaturized quantum devices.
  • The integrated miniature ion pump effectively achieves UHV.
  • This technology advances the development of compact quantum sensors and atomic clocks.