Related Experiment Video
Updated: Jun 22, 2025

Amplification of Near Full-length HIV-1 Proviruses for Next-Generation Sequencing
Published on: October 16, 2018
Comparing Gold-Standard Sanger Sequencing with Two Next-Generation Sequencing Platforms of HIV-1 gp160 Single Genome
David J Nolan1, Jonathan DaRoza1, Robin Brody2
1Bioinfoexperts LLC, Thibodaux, Louisiana, USA.
Abstract:
Our goal was to assess the accuracy of next generation sequencing (NGS) compared with Sanger. We performed single genome amplification (SGA) of HIV-1 gp160 on extracted tissue DNA from two HIV+ individuals. Amplicons (n = 30) were sequenced with Sanger or reamplified with barcoded primers and pooled before sequencing using Oxford Nanopore Technologies (ONT) and Pacific Biosciences (PB). For each amplicon, a consensus sequence for NGS reads was obtained by (1) mapping reads to the Sanger sequence when available ("reference-based") or (2) mapping reads to a "pseudo-reference" sequence, i.e., a consensus sequence of a subset of NGS reads ("reference-free"). PB reads were clustered based on genetic similarity. A Sanger consensus sequence was obtained for 23/30 amplicons, for which all NGS consensus sequences were identical (n = 9) or nearly identical (n = 14) compared with Sanger. For the nine mismatches between Sanger/NGS, the nucleotide in the NGS sequence matched all other sequences from that patient. Of the 7/30 amplicons without a Sanger sequence, NGS sequences had ≥35 ambiguous calls in five amplicons and 0 ambiguities in two amplicons. Analysis of the electropherograms showed failure of a single sequencing primer for the latter two amplicons (consistent with a single template) and overlapping peaks for the other five (consistent with multiple templates). Clustering results closely followed the Sanger/NGS consensus results, where amplicons derived from a single template also had a single cluster and vice versa (with one exception, which could be the result of barcode misidentification). Representative sequences from the clusters contained 2-13 differences compared with Sanger/NGS. In summary, we show that both ONT and PB can produce amplicon consensus sequences with similar or higher accuracy compared with Sanger and, importantly, without the need for a known reference sequence. Clustering could be useful in some circumstances to predict or confirm the presence of multiple starting templates.
More Related Videos
13:58Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011
19:57An Affordable HIV-1 Drug Resistance Monitoring Method for Resource Limited Settings
Published on: March 30, 2014
Related Concept Videos
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features....
Sanger Sequencing