Related Experiment Video
Updated: Jun 22, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Zenith angle dependence on cosmic-ray background in HPGe gamma spectrometers by using GEANT4 simulation
Hai Vo Hong1, Hung Nguyen Quoc2, Phuc Nguyen Tri Toan1
1Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science, 227 Nguyen Van Cu street, Ward 4, District 5, Ho Chi Minh City, Viet Nam; Vietnam National University, Linh Trung Ward, Thu Duc City, Ho Chi Minh City, Viet Nam.
Abstract:
In this study, we investigate the impact of zenith angle variations on cosmic-ray induced background in High-Purity Germanium (HPGe) gamma spectrometers using a coincidence technique based on plastic scintillator-Germanium detectors. We utilize an HPGe detector (Model GC2018 Mirion Ge Detector) enclosed within a low-activity cylindrical lead shield (Model 747E Mirion Lead Shield). For cosmic ray detection, a coincidence detection system with plastic scintillator detectors was positioned on top of the lead shielding. The zenith angle at the Germanium detector is computed using the dimensions of the square plastic scintillator and its distance from the Germanium detector center. We carried out measurements of cosmic-ray induced background in an HPGe gamma spectrometer with a square plastic configuration (80cm x 80cm), equivalent to a 45° zenith angle. The experimental measurements were compared with GEANT4 simulation data. The results demonstrate a good agreement between the measured energy spectrum and the simulated data across the energy range of 0.05 to 47 MeV. Further investigations into the effects of varying zenith angles provide valuable insights for optimizing HPGe spectrometer setups with minimized background interference.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
06:46Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab