Related Experiment Video
Updated: May 3, 2026

In Vivo Measurement of Hindlimb Dorsiflexor Isometric Torque from Pig
Published on: September 3, 2021
Bioimpedance as an alternative tool for subjective, visual scoring of a prevalent ham quality defect
Sisay Mebre Abie1, Paweł Suliga1, Bjørg Egelandsdal2
1Faculty of Ecology and Natural Resource Management, Norwegian University of Life Sciences, 1432 Ås, Norway.
Abstract:
The detection of meat quality defects can involve both subjective and objective methods. PSE-like meat is linked to a common pork defect and can be caused by rapid post-mortem damage of muscle fibers. This damage can again be linked to various factors, such as a low ultimate pH or a higher slaughter weight. PSE-like defects are characterized by discoloration, structural damage, and excessive moisture loss. However, the lack of suitable instrument-based methods makes the detection of PSE-like defects difficult, and subjective methods typically suffer from poorer reproducibility. The objective of this study was to establish how subjective visual evaluation correlates with electrical impedance spectroscopy and with traditional quality parameters. To do so, visual scoring was performed together with measurements of bioimpedance, color, and pH in two ham muscles (Adductor, Semimembranosus) for 136 animals 24-hours post-mortem. When comparing with visual scoring, Pearson correlation analysis shows the strongest correlation for bioimpedance (P , r = -0.46, R2 = 21%), followed by pHu (r = 0.44, R2 = 19%). When using all five quality measures, i.e., P , pHu, and CIELAB L * a * b *, the multivariate regression model had a prediction error of 0.76 for the visual scores. This was close to the error describing the subjective bias of visual scoring, more specifically the prediction error between the two observers (0.85). In all, P showed the strongest correlation among instrument-based quality tests and alone may be used for predicting pork ham structural defects, i.e., as an instrument-based alternative for subjective, visual scoring. However, an instrument that combines P with pH and/or L*a*b* would improve the prediction of PSE-like quality defects.
More Related Videos
Related Concept Videos
Enzyme Inhibition
Defenses Against Pathogens and Herbivores
Protein Folding Quality Check in the RER
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Quantifying and Rejecting Outliers: The Grubbs Test

