Tissue perfusion in DIEP flaps using Indocyanine Green Fluorescence Angiography, Hyperspectral imaging, and Thermal
Simone F Kleiss1, Marlies Michi2, Simone N Schuurman1
1Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Abstract:
Flap necrosis continues to occur in skin free flap autologous breast reconstruction. Therefore, we investigated the benefits of indocyanine green angiography (ICGA) using quantitative parameters for the objective, perioperative evaluation of flap perfusion. In addition, we investigated the feasibility of hyperspectral (HSI) and thermal imaging (TI) for postoperative flap monitoring. A single-center, prospective observational study was performed on 15 patients who underwent deep inferior epigastric perforator (DIEP) flap breast reconstruction (n=21). DIEP-flap perfusion was evaluated using ICGA, HSI, and TI using a standardized imaging protocol. The ICGA perfusion curves and derived parameters, HSI extracted oxyhemoglobin (oxyHb) and deoxyhemoglobin (deoxyHb) values, and flap temperatures from TI were analyzed and correlated to the clinical outcomes. Post-hoc quantitative analysis of intraoperatively collected data of ICGA application accurately distinguished between adequately and insufficiently perfused DIEP flaps. ICG perfusion curves identified the lack of arterial inflow (n=2) and occlusion of the venous outflow (n=1). In addition, a postoperatively detected partial flap epidermolysis could have been predicted based on intraoperative quantitative ICGA data. During postoperative monitoring, HSI was used to identify impaired perfusion areas within the DIEP flap based on deoxyHb levels. The results of this study showed a limited added value of TI. Quantitative, post-hoc analysis of ICGA data produced objective and reproducible parameters that enabled the intraoperative detection of arterial and venous congested DIEP flaps. HSI appeared to be a promising technique for postoperative flap perfusion assessment. A diagnostic accuracy study is needed to investigate ICGA and HSI parameters in real-time and demonstrate their clinical benefit.
More Related Videos
04:08Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
09:07The Superficial Inferior Epigastric Artery Axial Flap to Study Ischemic Preconditioning Effects in a Rat Model
Published on: January 27, 2023