Related Experiment Video
Updated: Aug 3, 2026

Surgical Retrieval, Isolation and In vitro Expansion of Human Anterior Cruciate Ligament-derived Cells for Tissue Engineering Applications
Published on: April 30, 2014
Peroneus Longus Tendon Autografts have Better Graft Diameter, Less Morbidity, and Enhanced Muscle Recuperation than
Deepu Jacob Punnoose1, Jacob Varghese1, Bipin Theruvil1
1Department of Orthopaedics, VPS Lakeshore Hospital, Kochi, 682040 Kerala India.
Background:
Recently the peroneus longus tendon (PLT) gained popularity in anterior cruciate ligament (ACL) reconstruction and has been utilized with satisfactory outcomes. However, there are concerns regarding donor site morbidity. This study aims to compare the functional outcome of ACL reconstruction using hamstring (HT) and PLT autografts and evaluate the donor site morbidity.
Methods:
Patients who underwent ACL reconstruction were allocated to two groups (HT and PLT). Graft diameter was measured intraoperatively. Knee functional outcome was evaluated with IKDC and Tegner-Lysholm scores preoperatively, and postoperatively after 3 months, 6 months, and 1 year. Donor site morbidities were assessed with thigh circumference measurements, subjective evaluation of sensory disturbances, and ankle scoring with AOFAS and FADI scores.
Results:
At 1-year follow-up, the PLT group showed comparable IKDC (p = 0.925) and Tegner-Lysholm (p = 0.600) scores with those of the HT group. The mean graft diameter in the PLT group (7.93 ± 0.52 mm) was larger compared with the HT group (7.43 ± 0.50 mm) (p < 0.001). The incidence of thigh atrophy (HT-16.7%, PLT-10%) and sensory disturbances (HT-73.3%, PLT-10%) was greater in the HT group. There was no significant ankle donor site morbidity in the PLT group (AOFAS-98.67 ± 3.45, FADI-99.23 ± 1.69).
Conclusion:
ACL reconstruction with PLT had comparable functional outcome with that of HT at 1 year. However, PLT demonstrated larger graft diameter, less donor site morbidity, and enhanced muscle recovery without significantly affecting the ankle function. PLT can be safely used as an acceptable alternative graft choice harvested from outside the knee for ACL reconstruction.