Related Experiment Video
Updated: Jun 22, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Finite element analysis of mechanical stress in a cementless tapered-wedge short stem in the varus position
Takahiro Maeda1,2, Osamu Obayashi3, Muneaki Ishijima4
1Department of Orthopedic Surgery, Toho University Graduate School of Medicine, 5-21-16 Omorinishi, Ota-ku, Tokyo, 143-8540, Japan.
Background:
In recent years, the use of tapered-wedge short stems has increased due to their ability to preserve bones and tendons. Surgical techniques occasionally result in a varus position of the stem, which is particularly pronounced in short stems. Although the varus position is not clinically problematic, there are reports of an increased incidence of stress shielding and cortical hypertrophy. Thus, we evaluated and examined the acceptable range of varus angles using finite element analysis.
Methods:
Patients diagnosed with osteoarthritis of the hip joint who had undergone arthroplasty were selected and classified into three types [champagne-flute (type A), intermediate (type B), and stovepipe (type C)]. Finite element analysis was performed using Mechanical Finder. The model was created using a Taperloc microplasty stem with the varus angle increased by 1° from 0° to 5° from the bone axis and classified into seven zones based on Gruen's zone classification under loading conditions in a one-leg standing position. The volume of interest was set, the mean equivalent stress for each zone was calculated.
Results:
A significant decrease in stress was observed in zone 2, and increased stress was observed in zones 3 and 4, suggesting the emergence of a distal periosteal reaction, similar to the results of previous studies. In zone 2, there was a significant decrease in stress in all groups at a varus angle ≥ 3°. In zone 3, stress increased from ≥ 3° in type B and ≥ 4° in type C. In zone 4, there was a significant increase in stress at varus angles of ≥ 2° in types A and B and at ≥ 3° in type C.
Conclusion:
In zone 2, the varus angle at which stress shielding above Engh classification grade 3 may appear is expected to be ≥ 3°. Distal cortical hypertrophy may appear in zones 3 and 4; the narrower the medullary cavity shape, the smaller the allowable angle of internal recession, and the wider the medullary cavity shape, the wider the allowable range. Long-term follow-up is required in patients with varus angles > 3°.
Related Concept Videos
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each...
Saint-Venant's Principle
Stress Concentrations in Circular Shafts
Design of Transmission Shafts - Stress Analysis

