Related Experiment Video
Updated: May 7, 2026

Indirect Fabrication of Lattice Metals with Thin Sections Using Centrifugal Casting
Published on: May 14, 2016
Microstructural and mechanical characterization of six Co-Cr alloys made by conventional casting and selective laser
Youssef S Al Jabbari1, Konstantinos Dimitriadis2, Aref Sufyan3
1Director, Dental Biomaterials Research and Development Chair and Professor, Prosthetic Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
Statement Of Problem:
Three Co-Cr alloy types (Co-Cr-Mo, Co-Cr-W, and Co-Cr-Mo-W) have been commonly used in the fabrication of dental prostheses. These alloys can be manufactured using either conventional casting or selective laser melting (SLM) techniques. Nevertheless, research that directly compares these materials and/or manufacturing processes in terms of their microstructural and mechanical characteristics is sparse.
Purpose:
The purpose of this in vitro study was to conduct microstructural and mechanical analysis via X-ray interpretation, optical microscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS), image analysis, X-ray diffraction (XRD), instrumented indentation testing (IIT), and 3-point bending testing to characterize Co-Cr-Mo, Co-Cr-W, and Co-Cr-Mo-W alloys produced through conventional casting and SLM.
Material And Methods:
Six Co-Cr-based alloys were analyzed and divided into 3 types based on their elemental composition (Co-Cr-Mo, Co-Cr-W, and Co-Cr-Mo-W). Additionally, each group was categorized based on the manufacturing process used (casting or SLM). X-ray scans were used to assess porosity. The microstructures of the specimens were assessed through SEM/EDS examination and XRD analysis. IIT was used to determine the Martens hardness (HM) and elastic index (ηIT), while the elastic modulus (E) was estimated through the 3-point bending test. The mechanical properties were statistically analyzed using 2-way analysis of variance (ANOVA) and the Tukey multiple comparison post hoc test, with alloy type and manufacturing process as discriminating variables (α=.05).
Results:
All cast groups exhibited gross porosity, while no pores or other flaws were found in the SLM groups. Based on the XRD results, the crystalline structure of all Co-Cr specimens consisted of the face-centered cubic γ phase (γ-fcc), along with the hexagonal close-packed ε phase (ε-hcp) and Cr23C6 carbide. Different microstructures were identified between the cast and SLM alloys. Significant differences were identified for the mean standard deviation HM (ranging from 2601 ±94 N/mm2 to 3633 ±61 N/mm2) and mean ±standard deviation ηIT (ranging from 16.8 ±0.3% to 20.9 ±0.3%) among alloys prepared by the same manufacturing process, while all SLM alloys had statistically higher HM and ηIT results than their cast counterparts (P<.05). No statistically significant differences were identified for the mean ±standard deviation Eb (ranging from 170 ±25 GPa to 244 ±36 GPa) among the groups prepared with the same manufacturing process (P>.05), but the SLM alloys had significantly higher results (P<.05) than the cast alloys.
Conclusions:
In general, the manufacturing procedure significantly affected the porosity, microstructure, and mechanical properties of the tested Co-Cr alloys. SLM decreased the internal porosity, provided a uniform microstructure, and improved the mechanical properties for all the tested alloy types.
More Related Videos
14:51An Available Technique for Preparation of New Cast MnCuNiFeZnAl Alloy with Superior Damping Capacity and High Service Temperature
Published on: September 23, 2018
08:55Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
Published on: June 7, 2018
Related Concept Videos
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability. Many...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...