Related Experiment Video
Updated: Jun 22, 2025

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
Published on: October 6, 2023
A Novel Radiology Communication Tool to Reduce Workflow Interruptions: Clinical Evaluation of RadConnect
Merlijn Sevenster1,2, Kenneth F M Hergaarden3, Omar Hertgers3
1Royal Philips Electronics, High Tech Campus 34, 5656AE, Eindhoven, The Netherlands. merlijn.sevenster@philips.com.
Abstract:
Despite the importance of communication, radiology departments often depend on communication tools that were not created for the unique needs of imaging workflows, leading to frequent radiologist interruptions. The objective of this study was test the hypothesis that a novel asynchronous communication tool for the imaging workflow (RadConnect) reduces the daily average number of synchronous (in-person, telephone) communication requests for radiologists. We conducted a before-after study. Before adoption of RadConnect, technologists used three conventional communication methods to consult radiologists (in-person, telephone, general-purpose enterprise chat (GPEC)). After adoption, participants used RadConnect as a fourth method. Technologists manually recorded every radiologist consult request related to neuro and thorax CT scans in the 40 days before and 40 days after RadConnect adoption. Telephone traffic volume to section beepers was obtained from the hospital telephone system for the same period. The value and usability experiences were collected through an electronic survey and structured interviews. RadConnect adoption resulted in 53% reduction of synchronous (in-person, telephone) consult requests: from 6.1 ± 4.2 per day to 2.9 ± 2.9 (P < 0.001). There was 77% decrease (P < 0.001) in telephone volume to the neuro and thorax beepers, while no significant volume change was noted to the abdomen beeper (control group). Survey responses (46% response rate) and interviews confirmed the positive impact of RadConnect on interruptions. RadConnect significantly reduced radiologists' telephone interruptions. Study participants valued the role-based interaction and prioritized worklist overview in the survey and interviews. Findings from this study will contribute to a more focused work environment.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Related Concept Videos
Radiological Investigation I: X-ray and CT
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...