Gabriele Bianco1,2, Matteo Boattini2,3,4, Sara Comini5
1Department of Experimental Medicine, University of Salento, Lecce, Italy.
Objectives:
The measurement of VOCs release in the headspace of a bacterial culture represents a new approach to rapidly assess antimicrobial susceptibility. Herein, we evaluated the diagnostic performance of the VITEK® REVEAL™ system directly from a collection of Gram-negative positive blood cultures.
Materials And Methods:
One hundred and twenty-eight positive blood cultures were included in the analysis (Enterobacterales, n = 95; Pseudomonas aeruginosa, n = 21; Acinetobacter baumannii complex, n = 12). Samples were processed using VITEK® REVEAL™ according to the manufacturer's recommendations, and MICs of 22 antimicrobials were compared with those obtained using reference methods. Categorical agreement (CA), essential agreement (EA) and categorical errors were calculated.
Results:
Overall, 2220 strain/antibiotic pair combinations were analysed. Of these, most were classified as resistant by reference antimicrobial susceptibility testing (1091/2220; 48.7%). The overall CA and EA were 97.6% and 97.7%, respectively. CA ranged from 97.5% in Enterobacterales to 97.9% in both P. aeruginosa and A. baumannii complex. The overall number of categorical discrepancies were: 18 very major errors (1.6%), 13 major errors (1.2%) and 22 minor errors (2.4%). EA ranged from 95.2% in P. aeruginosa to 98.1% in Enterobacterales. Screening test for ESBL phenotype was positive, indeterminate and negative in 13.7%, 32.6% and 27.4% of Enterobacterales isolates tested by both VITEK® REVEAL™ and the reference method, showing 100% CA.
Conclusions:
VITEK® REVEAL™ represents a reliable tool to obtain antimicrobial susceptibility results of the main Gram-negative species directly from positive blood cultures with time to results of less than 8 h.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
09:07Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
Published on: May 24, 2024
Related Concept Videos
MALDI-TOF Mass Spectrometry
Antimicrobial Effectiveness
Rapid Identification of Pathogens
Automated Microbial Diagnostics