Related Experiment Video
Updated: Jun 22, 2025

Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
Fast and Greener Ultrasound-Assisted Acid Extraction for the Determination of Potentially Toxic Elements in
Vitor Busto Duarte1, Felippe Ceraso Gonçalves1, Júlia Concordido Guimarães1
1Chemistry Institute, Federal University of Rio de Janeiro (IQ/UFRJ), Analytical Chemistry Department, Avenue Athos da Silveira Ramos, N° 149, Block A, 5th Floor, Technology Center, University City, Rio de Janeiro, RJ 21941-909, Brazil.
Background:
Understanding the chemical composition of fluorescent lamp residue, particularly potentially toxic elements, is crucial for reducing environmental impacts and human health risks after disposal. However, the challenge lies in effectively analyzing these heterogeneous solid samples. Techniques involving quantitative dissolution become imperative, playing a fundamental role in quantifying trace elements.
Objective:
The aim of this work is to develop and present a new, faster, and more efficient and environmentally friendly method using ultrasound-assisted acid extraction to quantify potentially toxic elements (Cu, Mn, Ni, Sr, and Zn) present in fluorescent lamp waste using the inductively coupled plasma-optical emission spectrometry technique.
Methods:
An ultrasound-assisted acid extraction method for the quantification of potentially toxic elements in fluorescent lamp waste was developed and applied as a greener alternative to conventional digestion methods. For variable optimization, a full factorial design with two levels and two variables (time and temperature) was used to determine which factors significantly affected the observed response.
Results:
The results obtained for the developed extraction method were compared with a reference method employing a heating acid digestion (with a mixture of HCl, HClO4, and HF) using statistical tools. The best results were obtained using an extraction time of 10 min and a temperature of 25°C. Inductively coupled plasma optical emission spectrometry was applied for element quantification.
Conclusion:
The proposed extraction method showed good results for Cu, Mn, Ni, Sr, and Zn. Furthermore, the proposed method based on ultrasound radiation presents additional criteria that align with the concepts of green analytical chemistry.
Highlights:
A greener alternative method for the determination of Cu, Mn, Ni, Sr, and Zn in fluorescent lamp waste was developed. Optimal conditions for ultrasound extraction of potentially toxic elements were achieved in 10 min at a temperature of 25°C. Environmentally friendly aspects of ultrasound align with the requirements of green analytical chemistry.
More Related Videos
06:53Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Fluorescence Spectroscopy
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....