Related Experiment Video
Updated: Aug 13, 2026

Measuring and Manipulating Functionally Specific Neural Pathways in the Human Motor System with Transcranial Magnetic Stimulation
Published on: February 23, 2020
A comparison of techniques to determine active motor threshold for transcranial magnetic stimulation research
Jonathan P Beausejour1, Jay Rusch2, Kevan S Knowles1
1Cognition, Neuroplasticity, and Sarcopenia Laboratory, Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, USA; School of Kinesiology and Rehabilitation Sciences, University of Central Florida, Orlando, FL, USA.
Abstract:
The determination of active motor threshold (AMT) is a critical step in transcranial magnetic stimulation (TMS) research. As AMT is frequently determined using an absolute electromyographic (EMG) threshold (e.g., 200 µV peak-to-peak amplitude), wide variation in EMG recordings across participants has given reason to consider relative thresholds (e.g., = 2 × background sEMG) for AMT determination. However, these approaches have not been systemically compared. Our purpose was to compare AMT estimations derived from absolute and relative criteria commonly used in the quadriceps, and assess the test-retest reliability of each approach. We used a repeated measures design to assess AMT estimations in the vastus lateralis (VL) from eighteen young adults (9 males and 9 females; mean ± SD age = 23 ± 2 years) across two laboratory visits. AMT was determined for each criterion, at each lab visit. A paired samples t-test was used to compare mean differences in AMT estimations during the second laboratory visit. Paired samples t-tests and intraclass correlation coefficients (ICC2,1) were calculated to assess test-retest reliability of each criterion. Differences between the criteria were small and not statistically significant (p = 0.309). The absolute criterion demonstrated moderate to excellent reliability (ICC2,1 = 0.866 [0.648-0.950]), but higher AMTs were observed in the second visit (p = 0.043). The relative criteria demonstrated good-to-excellent test-retest reliability (ICC2,1 = 0.894 [0.746-0.959]) and AMTs were not different between visits (p = 0.420). TMS researchers aiming to track corticospinal characteristics across visits should consider implementing relative criterion approaches during their AMT determination protocol.
More Related Videos
08:24Conventional and Threshold-Tracking Transcranial Magnetic Stimulation Tests for Single-handed Operation
Published on: August 16, 2021
14:47Author Spotlight: Combined Peripheral Nerve Stimulation and Controllable Pulse Parameter Transcranial Magnetic Stimulation to Probe Sensorimotor Control and Learning
Published on: April 21, 2023
Related Concept Videos
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform magnetic...
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Back EMF
Magnetic Resonance Imaging
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...