Relative Timing of Mammography and MRI for Breast Cancer Screening: Impact on Performance Evaluation
Janie M Lee1, Laura E Ichikawa2, Karla Kerlikowske3
1Section Chief of Breast Imaging, Department of Radiology, University of Washington School of Medicine, Seattle, Washington; Director of Breast Imaging, Fred Hutchinson Cancer Center, Seattle, Washington.
Objective:
Mammography and MRI screening typically occur in combination or in alternating sequence. We compared multimodality screening performance accounting for the relative timing of mammography and MRI and overlapping follow-up periods.
Methods:
We identified 8,260 screening mammograms performed 2005 to 2017 in the Breast Cancer Surveillance Consortium, paired with screening MRIs within ±90 days (combined screening) or 91 to 270 days (alternating screening). Performance for combined screening (cancer detection rate [CDR] per 1,000 examinations and sensitivity) was calculated with 1-year follow-up for each modality, and with a single follow-up period treating the two tests as a single test. Alternating screening performance was calculated with 1-year follow-up for each modality and also with follow-up ending at the next screen if within 1 year (truncated follow-up).
Results:
For 3,810 combined screening pairs, CDR per 1,000 screens was 6.8 (95% confidence interval [CI]: 4.6-10.0) for mammography and 12.3 (95% CI: 9.3-16.4) for MRI as separate tests compared with 13.1 (95% CI: 10.0-17.3) as a single combined test. Sensitivity of each test was 48.1% (35.0%-61.5%) for mammography and 79.7% (95% CI: 67.7%-88.0%) for MRI compared with 96.2% (95% CI: 85.9%-99.0%) for combined screening. For 4,450 alternating screening pairs, mammography CDR per 1,000 screens changed from 3.6 (95% CI: 2.2-5.9) to zero with truncated follow-up; sensitivity was incalculable (denominator = 0). MRI CDR per 1,000 screens changed from 12.1 (95% CI 9.3-15.8) to 11.7 (95% CI: 8.9-15.3) with truncated follow-up; sensitivity changed from 75.0% (95% CI 63.8%-83.6%) to 86.7% (95% CI 75.5%-93.2%).
Discussion:
Updating auditing approaches to account for combined and alternating screening sequencing and to address outcome attribution issues arising from overlapping follow-up periods can improve the accuracy of multimodality screening performance evaluation.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...