Related Experiment Video
Updated: Jun 21, 2025

Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
Frequency-hopping along with resolution-turning for fast and enhanced reconstruction in ultrasound tomography
Tran Quang-Huy1, Bhisham Sharma2, Luong Thi Theu3
1Faculty of Physics, Hanoi Pedagogical University 2, Xuan Hoa Ward, Phuc Yen City, Vinh Phuc Province, Vietnam.
Abstract:
The distorted Born iterative (DBI) method is considered to obtain images with high-contrast and resolution. Besides satisfying the Born approximation condition, the frequency-hopping (FH) technique is necessary to gradually update the sound contrast from the first iteration and progress to the actual sound contrast of the imaged object in subsequent iterations. Inspired by the fact that the higher the frequency, the higher the resolution. Because low-frequency allows for low-resolution object imaging, hence for high-resolution imaging requirements, using low-frequency to possess a high-resolution image from the first iteration will be less efficient. For an effective reconstruction, the object's resolution at low frequencies should be small. And similarly, with high frequencies, the object resolution should be larger. Therefore, in this paper, the FH, and the resolution-turning (RT) technique are proposed to obtain object images with high-contrast and -resolution. The convergence speed in the initial iterations is rapidly achieved by utilizing low frequency in the frequency-turning technique and low image resolution in the resolution-turning technique. It is crucial to ensure accurate object reconstruction for subsequent iterations. The desired spatial resolution is attained by employing high frequency and large image resolution. The resolution-turning distorted Born iterative (RT-DBI) and frequency-hopping distorted Born iterative (FH-DBI) solutions are thoroughly investigated to exploit their best performance. This makes sense because if it is not good to choose the number of iterations for the frequency f1 in FH-DBI and for the resolution of N1 × N1 in RT-DBI, then these solutions give even worse quality than traditional DBI. After that, the RT-FH-DBI integration was investigated in two sub-solutions. We found that the lower frequency f1 used both before and after the RT would get the best performance. Consequently, compared to the traditional DBI approaches, the normalized error and total runtime for the reconstruction process were dramatically decreased, at 83.6% and 18.6%, respectively. Besides fast and quality imaging, the proposed solution RT-FH-DBI is promised to produce high-contrast and high-resolution object images, aiming at object reconstruction at the biological tissue. The development of 3D imaging and experimental verification will be studied further.
More Related Videos
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
08:523D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue
Published on: November 27, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Reconstruction of Signal using Interpolation