Related Experiment Video
Updated: Jun 21, 2025

Diffuse Reflectance Infrared Spectroscopic Identification of Dispersant/Particle Bonding Mechanisms in Functional Inks
Published on: May 8, 2015
Using the refractive index of latent fingerprints for the quantification and characterisation of sample deposition
1King's Forensics, Department of Analytical, Environmental & Forensic Sciences, Franklin-Wilkins Building, King's College London, 150 Stamford Street, London SE1 9NH, UK.
Abstract:
Latent fingerprints (LFPs) are predominantly used for personal identification, but in recent years research has shown their potential for drug screening. Despite this there is no standardised collection method to allow accurate drug test interpretation. We sought to help address this by characterising different variables related to sweat deposition in LFPs as the knowledge is limited. A series of experiments were conducted firstly to validate a novel tool called the Ridgeway (Intelligent Fingerprint Ltd. UK) to quantify the amount of sweat deposited from a LFP using the refractive index (RI). A significant positive correlation was observed between the Ridgeway score (Rs) and LFP mass [r = 0.868, p < 0.01]. The Rs was used as means to investigate optimal sampling to characterise sample deposition for drug screening purposes. It was found with a consistent disposition pressure (300 - 400 g) and surface (glass slide) no significant difference was observed between the left and right index finger [left: p = 0.938; right: p = 0.838]. Significantly higher Rs [p<0.01] were obtained when 10 cumulative LFPs were deposited compared to a single LFP, suggesting a larger sweat quantity. We also wanted to investigate optimal eccrine sweat sampling to confirm drug ingestion over drug contamination of the fingerprint. We found that wearing gloves did not significantly improve mean difference in Rs when compared to no gloves [p = 0.239]. To produce eccrine only LFPs, external contamination (e.g. sebaceous sweat) needs to be removed. Soap with lint free tissue was significantly better for this compared to antibacterial hand gel [p<0.01]. Our findings showed that the Ridgeway tool effectively quantified LFPs at the point of deposition using a refractive index and enabled us to establish conditions for consistent LFP sampling.
More Related Videos
08:12Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
Published on: March 13, 2013
04:32Author Spotlight: Quantitative Characterization of Liquid Photosensitive Bioink Properties for Continuous Digital Light Processing Based Printing
Published on: April 14, 2023
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Total Internal Reflection Fluorescence Microscopy
IR Frequency Region: Fingerprint Region