Related Experiment Video
Updated: Jun 21, 2025

Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation
Published on: June 26, 2018
Epidural spread of surgical site infection from spinal cord stimulation trial
Taif Mukhdomi1, Bennett Andrassy1, Semih Gungor2,3
1Pain Labs, New Albany, OH 43054, USA.
Abstract:
We present a case of deep surgical site infection (SSI) at a spinal cord stimulator (SCS) trial implantation site, resulting from an allergic reaction to an unknown agent. A 38-year-old female with complex regional pain syndrome began an SCS trial, noting 100% pain relief for 5 days. Fluid drainage from the surgical site was reported on POD6 and trial leads were removed the following day. The patient was hospitalized with sepsis. Blood cultures revealed Staphylococcus aureus. MRIs showed skin breakdown and cellulitis of the paraspinal musculature extending into the epidural space. The patient was maintained with antibiotics and rigorous wound care for 9 days and the surgical site infection resolved. The patient proceeded to SCS implantation, and reported good pain relief with the implanted device.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Spinal Anesthesia