First-Order Derivative Spectrophotometry for Simultaneous Determination of Vitamin C and Nicotinamide: Application in

Clóvis A Balbinot Filho1, Renata F Teixeira1, Jônatas L Dias1

  • 1Department of Chemical and Food Engineering, Federal University of Santa Catarina, UFSC, PO Box 476, 88040-900 Florianópolis, SC, Brazil.

ACS Omega
|July 8, 2024
PubMed

Related Concept Videos

Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
8.5K
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
4.6K
UV–Vis Spectroscopy of Conjugated Systems01:32

UV–Vis Spectroscopy of Conjugated Systems

Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is...
5.9K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
4.1K
Measurement of Bioavailability: Pharmacokinetic Methods01:30

Measurement of Bioavailability: Pharmacokinetic Methods

Pharmacokinetics is a vital branch of pharmacology that examines how drugs are absorbed, distributed, metabolized, and excreted by the body. Two key methodologies in pharmacokinetics are plasma drug concentration studies and urinary drug excretion analyses, both of which provide critical insights into a drug's therapeutic efficacy and bioavailability.Plasma Drug Concentration-Time StudiesPlasma drug concentration-time studies involve analyzing blood samples at specific intervals to quantify...
528
Measurement of Bioavailability: Pharmacodynamic Methods01:20

Measurement of Bioavailability: Pharmacodynamic Methods

Pharmacodynamic methods provide insights into a drug's effects on physiological processes over time and play a crucial role in understanding bioavailability and therapeutic efficacy. These methods can be broadly classified into acute pharmacological and therapeutic response approaches, each with distinct mechanisms and applications.The acute pharmacological response method directly correlates a drug's physiological effects, such as ECG or pupil diameter changes, to its time course in the body.