Related Experiment Video
Updated: Jun 21, 2025

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Validation of a Novel Mobile Application for Assessing Pediatric Tracheostomy Emergency Simulations
Marc-Mina Tawfik1, Elliot Schiff1, Roxanna Mosavian1
1Albert Einstein College of Medicine Bronx New York USA.
Objective:
Pediatric tracheostomy is associated with high morbidity and mortality, yet clinician knowledge and quality of tracheostomy care may vary widely. In situ simulation is effective at detecting and mitigating related latent safety threats, but evaluation via retrospective video review has disadvantages (eg, delayed analysis, and potential data loss). We evaluated whether a novel mobile application is accurate and reliable for assessment of in situ tracheostomy emergency simulations.
Methods:
A novel mobile application was developed for assessment of tracheostomy emergency in situ simulation team performance. After 1.25 hours of training, 6 raters scored 10 tracheostomy emergency simulation videos for the occurrence and timing of 12 critical steps. To assess accuracy, rater scores were compared to a reference standard to determine agreement for occurrence or absence of critical steps and a timestamp within ±5 seconds. Interrater reliability was determined through Cohen's and Fleiss' kappa and intraclass correlation coefficient.
Results:
Raters had 86.0% agreement with the reference standard when considering step occurrence and timing, and 92.8% agreement when considering only occurrence. The average timestamp difference from the reference standard was 1.3 ± 18.5 seconds. Overall interrater reliability was almost perfect for both step occurrence (Fleiss' kappa of 0.81) and timing of step (intraclass correlation coefficient of 0.99).
Discussion:
Using our novel mobile application, raters with minimal training accurately and reliably assessed videos of tracheostomy emergency simulations and identified areas for future refinement.
Implications For Practice:
With refinements, this innovative mobile application is an effective tool for real-time data capture of time-critical steps in in situ tracheostomy emergency simulations.
Related Concept Videos
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...