Related Experiment Video
Updated: Jun 21, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19
Philip Yang1, Ismail A Gregory1, Chad Robichaux2
1Division of Pulmonary, Allergy, Critical Care, and Sleep Medicine, Emory University, Atlanta, GA.
Objectives:
To develop and validate machine learning (ML) models to predict high-flow nasal cannula (HFNC) failure in COVID-19, compare their performance to the respiratory rate-oxygenation (ROX) index, and evaluate model accuracy by self-reported race.
Design:
Retrospective cohort study.
Setting:
Four Emory University Hospitals in Atlanta, GA.
Patients:
Adult patients hospitalized with COVID-19 between March 2020 and April 2022 who received HFNC therapy within 24 hours of ICU admission were included.
Interventions:
None.
Measurements And Main Results:
Four types of supervised ML models were developed for predicting HFNC failure (defined as intubation or death within 7 d of HFNC initiation), using routine clinical variables from the first 24 hours of ICU admission. Models were trained on the first 60% (n = 594) of admissions and validated on the latter 40% (n = 390) of admissions to simulate prospective implementation. Among 984 patients included, 317 patients (32.2%) developed HFNC failure. eXtreme Gradient Boosting (XGB) model had the highest area under the receiver-operator characteristic curve (AUROC) for predicting HFNC failure (0.707), and was the only model with significantly better performance than the ROX index (AUROC 0.616). XGB model had significantly worse performance in Black patients compared with White patients (AUROC 0.663 vs. 0.808, p = 0.02). Racial differences in the XGB model were reduced and no longer statistically significant when restricted to patients with nonmissing arterial blood gas data, and when XGB model was developed to predict mortality (rather than the composite outcome of failure, which could be influenced by biased clinical decisions for intubation).
Conclusions:
Our XGB model had better discrimination for predicting HFNC failure in COVID-19 than the ROX index, but had racial differences in accuracy of predictions. Further studies are needed to understand and mitigate potential sources of biases in clinical ML models and to improve their equitability.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: