Related Experiment Video
Updated: Jun 21, 2025

Area-based Image Analysis Algorithm for Quantification of Macrophage-fibroblast Cocultures
Published on: February 15, 2022
Evaluation of Cellpose segmentation with sequential thresholding for instance segmentation of cytoplasms within
Nianchao Wang1, Linghao Hu1, Alex J Walsh1
1Texas A&M University, 3120 TAMU, College Station, 77840, United States.
Background:
Autofluorescence imaging of the coenzyme, reduced nicotinamide adenine dinucleotide (phosphate) (NAD(P)H), provides a label-free technique to assess cellular metabolism. Because NAD(P)H is localized in the cytosol and mitochondria, instance segmentation of cell cytoplasms from NAD(P)H images allows quantification of metabolism with cellular resolution. However, accurate cytoplasmic segmentation of autofluorescence images is difficult due to irregular cell shapes and cell clusters.
Method:
Here, a cytoplasm segmentation method is presented and tested. First, autofluorescence images are segmented into cells via either hand-segmentation or Cellpose, a deep learning-based segmentation method. Then, a cytoplasmic post-processing algorithm (CPPA) is applied for cytoplasmic segmentation. CPPA uses a binarized segmentation image to remove non-segmented pixels from the NAD(P)H image and then applies an intensity-based threshold to identify nuclei regions. Errors at cell edges are removed using a distance transform algorithm. The nucleus mask is then subtracted from the cell segmented image to yield the cytoplasm mask image. CPPA was tested on five NAD(P)H images of three different cell samples, quiescent T cells, activated T cells, and MCF7 cells.
Results:
Using POSEA, an evaluation method tailored for instance segmentation, the CPPA yielded F-measure values of 0.89, 0.87, and 0.94 for quiescent T cells, activated T cells, and MCF7 cells, respectively, for cytoplasm identification of hand-segmented cells. CPPA achieved F-measure values of 0.84, 0.74, and 0.72 for Cellpose segmented cells.
Conclusion:
These results exceed the F-measure value of a comparative cell segmentation method (CellProfiler, ∼0.50-0.60) and support the use of artificial intelligence and post-processing techniques for accurate segmentation of autofluorescence images for single-cell metabolic analyses.