Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
The induced defocus by Defocus Incorporated Soft Contact lenses is dependent on visual distance and ambient
Jiangdong Hao1,2,3, Zhenghua Lin2,3,4, Xiaoyun Xi2,3
1Aier Academy of Ophthalmology, Central South University, Changsha, China.
Purpose:
Defocus Incorporated Soft Contact (DISC) lenses, a commonly used type of multifocal lens in clinical practice, may slow down myopia progression by inducing myopic retinal defocus. The purpose of this study was to explore whether the induced defocus across the retina could be affected by visual environments encountered in the real world, such as differences in viewing distance and ambient illuminance.
Methods:
In this cross-over trial, 30 myopic adults wore both DISC lenses and single vision contact (SVC) lenses in random order. An open-view Hartmann-Shack scanning wavefront sensor was used to measure defocus at different retinal locations along the horizontal meridian under four experimental conditions: far target (3 m) and near targets (0.33 m) under scotopic (<1 lux) or photopic (~300 lux) conditions.
Results:
The results showed that DISC lenses induced more myopic retinal defocus than SVC lenses in all conditions (all p < 0.05), except for the scotopic near target. In addition, for DISC lenses, the defocus was greater in the photopic than the scotopic conditions for both the far and near targets (both p < 0.05).
Conclusion:
In conclusion, the retinal defocus induced by these multifocal lenses was dependent on both visual distance and ambient illuminance, indicating that the visual conditions might affect the anti-myopia efficacy of these devices.
More Related Videos
Related Concept Videos
Focusing of Light in the Eye
Depth Perception and Spatial Vision
Photoreceptors and Visual Pathways
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy