Related Experiment Video
Updated: Aug 14, 2026

Quantification of Strain in a Porcine Model of Skin Expansion Using Multi-View Stereo and Isogeometric Kinematics
Published on: April 16, 2017
Safety Profile Comparison of 2 Smooth Tissue Expander Types: Artoura and CPX4
Mariana N Almeida1, David P Alper, Mica C G Williams
1From the Division of Plastic Surgery, Department of Surgery, Yale School of Medicine, New Haven, CT.
Introduction:
With the recent transition to smooth tissue expanders (TEs), functional differences between TE subtypes have not been fully elucidated. This study evaluated the differences in TE characteristics and complications between 2 commonly used Mentor smooth TE models, Artoura and CPX4.
Methods:
A retrospective review of patients who received either smooth Mentor Artoura or CPX4 TE from 2012 to 2022 was conducted. Demographic data, perioperative information, pain scores, TE variables, cancer characteristics, and complications were collected. A multivariate analysis was used to evaluate the relationship between TE subtype and complications while controlling for demographic, TE characteristics, radiation, and chemotherapy exposure.
Results:
During the study period, 62 smooth Artoura TEs and 79 smooth CPX4 TEs were used. Patients who received CPX4 smooth implants tended to be older (51.09 vs 46.18 years old, P = 0.02) and have a higher body mass index (28.66 vs 23.50 kg/m 2 , P < 0.001). There were no differences among patient comorbidities. CPX4 required on average a greater total fill volume (422.23 vs 348.07 mL, P = 0.01) and had a greater drain duration (16.91 vs 14.33 days, P = 0.05). There were no differences in TE plane placement between Artoura and CPX4. Additionally, there were no differences in complication rates, including infection, hematomas, seromas, wound breakdown, TE replacement, and capsular contracture. When controlling for body mass index, diabetes, TE plane placement, acellular dermal matrix use, radiation exposure, and chemotherapy, there was no association between TE subtype and any individual complication.
Discussion:
Differences in total fill volume and drain duration were significantly different between Mentor Artoura and CPX4 implants, which may influence TE subtype selection. However, Artoura and CPX4 have excellent and equivalent safety profiles with similar complication rates, even when controlling for demographic and TE characteristics.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
Related Concept Videos
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller aligns...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...