Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Different surface treatments on recently introduced CAD-CAM resin-modified ceramics: Implications on bond strength
Miguel Ángel Saravia-Rojas1, Victor Abel Huanambal-Tiravanti2, Rocio Geng-Vivanco3
1Full Professor and Department Head, Academic Department of Stomatology Clinic, School of Dentistry, University of Cayetano Heredia, Lima, Peru.
Statement Of Problem:
The diverse chemical composition of recently introduced resin-modified ceramics complicates the establishment of a universally accepted clinical bonding protocol.
Purpose:
The purpose of this in vitro study was to evaluate the influence of different surface treatments of resin-modified ceramics on the bond strength to a resin cement.
Material And Methods:
Sixteen 10×12×3-mm resin-modified ceramic slices were obtained from each material (Cerasmart; GC, Shofu Block HC; Shofu, Vita Enamic; Vita, Evolux hybrid; BlueDent, Alium; Alium). Slices were assigned to 4 groups based on surface treatments: Control (no treatment), airborne-particle abrasion with Al2O3 (Al2O3), conditioning with 9% HF (HF), and Al2O3+HF. After treatments and silane coupling agent (Monobond N; Ivoclar) application, 7 resin cement cylinders (Choice 2 veneer; Bisco) were built on each slice and light polymerized for 20 seconds. Half of the specimens (n=14 cylinders) were stored for 24 hours, and the other half were thermocycled (20 000 cycles, 5 °C to 55 °C, 30-second dwell time). Microshear bond strength was tested and analyzed with 3-way ANOVA and the Tukey HSD test (α=.05), and failure patterns were classified. Surface morphology after treatments was observed with scanning electron microscopy and Raman spectroscopy.
Results:
After 24 hours, all treatments induced higher bond strength (P<.05) than in the control in Evolux. Al2O3+HF caused higher bond strength (P<.05) than in the control in Cerasmart and Shofu, and higher bond strength than Al2O3 in Cerasmart. However, it resulted in lower bond strength (P<.05) than Al2O3 in Alium. After thermocycling, irrespective of the resin-modified ceramic, all treatments induced higher bond strength (P<.05) than in the control. HF induced lower bond strength (P<.05) than Al2O3 in Alium. Al2O3+HF caused the highest bond strength (P<.05) in Evolux and higher bond strength (P<.05) than HF in Vita Enamic. Adhesive failures were prevalent under control conditions, and mixed failures were common after treatments. Al2O3 induced surface alterations in all resin-modified ceramics. HF notably altered Vita Enamic, while it had no noticeable impact on the other resin-modified ceramics. Al2O3+HF caused a considerable alteration in Vita Enamic and modified the other resin-modified ceramics. Vita Enamic had the characteristic vibrational bands of inorganic compounds, while the other resin-modified ceramics exhibited distinct bands associated with organic compounds.
Conclusions:
Airborne-particle abrasion with Al2O3 followed by HF yielded the highest bond strength, regardless of the resin-modified ceramic, except for Alium, which demonstrated better bond strength after airborne-particle abrasion with Al2O3. 9% HF for 30 seconds caused notable surface alterations in Vita Enamic, negatively impacting its bond strength. Vita Enamic was the only resin-modified ceramic displaying both organic and inorganic composition, while the other resin-modified ceramics showed predominantly organic composition.
More Related Videos
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Bonding and Strength of Aggregate
Mortar Properties
Hydration of Cement
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...