Amplification of negative gas adsorption in a multivariate framework

Francesco Walenszus1, Volodymyr Bon1, Ankita De1

  • 1Center of Inorganic Chemistry I, Dresden University of Technology, Bergstrasse 66, 01069 Dresden, Germany.

Chemical Communications (Cambridge, England)
|July 10, 2024
PubMed
Summary

Researchers fine-tuned flexible metal-organic frameworks (MOFs) by incorporating rigid linkers. This stabilized a key phase, doubling the gas expelled during negative gas adsorption transitions.

Related Concept Videos

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.0K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
4.1K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
740
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
586
Factorial Design02:01

Factorial Design

Factorial Analysis is an experimental design that applies Analysis of Variance (ANOVA) statistical procedures to examine a change in a dependent variable due to more than one independent variable, also known as factors. Changes in worker productivity can be reasoned, for example, to be influenced by salary and other conditions, such as skill level. One way to test this hypothesis is by categorizing salary into three levels (low, moderate, and high) and skills sets into two levels (entry level...
13.0K
Analyte Adsorption and Distribution01:09

Analyte Adsorption and Distribution

In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and...
633