Background:
Pulsed-field ablation (PFA) is an alternative to thermal ablation (TA) in patients with atrial fibrillation (AF) receiving catheter-based therapy for pulmonary vein isolation (PVI). However, its efficacy and safety have yet to be fully elucidated.
Objective:
The purpose of this study was to compare the acute and long-term efficacies and safety of PFA and TA.
Methods:
We performed a systematic review and meta-analysis of randomized and nonrandomized controlled trials comparing PFA and TA in patients with AF undergoing their first PVI ablation. The TA group was divided into cryoballoon (CB) and radiofrequency subgroups. AF patients were divided into paroxysmal atrial fibrillation (PAF) and persistent atrial fibrillation (PersAF) subgroups for further analysis.
Results:
Eighteen studies involving 4998 patients (35.2% PFA) were included. Overall, PFA was associated with a shorter procedure time (mean difference [MD] -21.68; 95% confidence interval [CI] -32.81 to -10.54) but longer fluoroscopy time (MD 4.53; 95% CI 2.18-6.88) than TA. Regarding safety, lower (peri-)esophageal injury rates (odds ratio [OR] 0.17; 95% CI 0.06-0.46) and higher tamponade rates (OR 2.98; 95% CI 1.27-7.00) were observed after PFA. In efficacy assessment, PFA was associated with a better first-pass isolation rate (OR 6.82; 95% CI 1.37-34.01) and a lower treatment failure rate (OR 0.83; 95% CI 0.70-0.98). Subgroup analysis showed no differences in PersAF and PAF. CB was related to higher (peri)esophageal injury, and lower PVI acute success and procedural time.
Conclusion:
Compared to TA, PFA showed better results with regard to acute and long-term efficacy but significant differences in safety, with lower (peri)esophageal injury rates but higher tamponade rates in procedural data.