Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Traditional radiography versus computed tomography to assess reduced distal radius fractures
Lente H M Dankelman1, Britt Barvelink2, Michael H J Verhofstad3
1Trauma Research Unit, Department of Surgery, Erasmus MC, University Medical Center Rotterdam, 3000 CA, P.O. Box 2040, Rotterdam, The Netherlands. l.dankelman@erasmusmc.nl.
Introduction:
This study compares computed tomography (CT) with plain radiography in its ability to assess distal radius fracture (DRF) malalignment after closed reduction and cast immobilization.
Methods:
Malalignment is defined as radiographic fracture alignment beyond threshold values according to the Dutch guideline encompassing angulation, inclination, positive ulnar variance and intra-articular step-off or gap. After identifying 96 patients with correct alignment on initial post-reduction radiographs, we re-assessed alignment on post-reduction CT scans.
Results:
Significant discrepancies were found between radiographs and CT scans in all measurement parameters. Notably, intra-articular step-off and gap variations on CT scans led to the reclassification of the majority of cases from correct alignment to malalignment. CT scans showed malalignment in 53% of cases, of which 73% underwent surgery.
Conclusion:
When there is doubt about post-reduction alignment based on radiograph imaging, additional CT scanning often reveals malalignment, primarily due to intra-articular incongruency.
More Related Videos
09:34A Method to Estimate Cadaveric Femur Cortical Strains During Fracture Testing Using Digital Image Correlation
Published on: September 14, 2017
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...