Institutional Experience of Routine Radiation Surveillance of Delay and Decay Tanks Facility in a Department Having
Amandeep Kaur1, Yasmeen Atwal Sonik1, Bhavay Sonik1
1Department of Nuclear Medicine, Guru Gobind Singh Medical College and Hospital, Faridkot, Punjab, India.
Background:
Radioactive solid and liquid waste generated by patients after high-dose iodine therapy may lead to significant radiation exposure if not properly handled.
Aims And Objectives:
This study was conducted to monitor the radiation exposure along the sewerage drainage system of the high-dose iodine therapy ward and to rule out leakage if any, that might pose a potential radiation hazard to the general public (sewerage workers) and radiation health professional.
Materials And Methods:
The sewerage drainage system from isolation wards has multiple gate valves to regulate sewerage flow from the high-dose iodine therapy ward into delay and decay tanks (DDT) built, especially for the purpose. Radiation surveillance was done using a Geiger-Muller counter-based survey meter at 11 different locations on a weekly basis for 12 weeks.
Results:
A total of 26 patients underwent high-dose iodine ablation therapy during the study period in our department, with the highest recorded radiation exposure rate in the sewerage draining system in the 9th week of patient admission. This was at the common gate valve junction (location B) that directed sewerage waste from all four isolation rooms into the common pipeline leading to DDT. Minimal radiation exposure was recorded within Atomic Energy Regulatory Board -prescribed limits with no evidence of leakage.
Conclusion:
A routine radiation survey is an important component of overall radiation safety in the nuclear medicine department, including sewerage delay tank facilities, which helps keep the radiation exposure to acceptable levels by identifying timely leakage.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...