Relationship between epidural catheter migration beneath the skin and subcutaneous fat thickness assessed using
Natsumi Sakamoto1, Mitsuhiro Matsuo2, Tomonori Takazawa1
1Department of Anesthesiology, Faculty of Medicine, University of Toyama, 2630 Sugitani, Toyama, 930-0194, Japan.
Purpose:
The causes of epidural catheter migration beneath the skin have not been previously investigated. We hypothesized that greater subcutaneous fat thickness might be associated with increased catheter migration beneath the skin.
Methods:
We conducted a retrospective cross-sectional study of patients who had undergone combined general and epidural anesthesia, selecting individuals who received thoracic and abdominal CT scans within the first 5 postoperative days. Needle depth was defined as the distance from the needle tip to the skin surface when the anesthesiologist determined that the needle tip had reached the epidural space. We measured the length of the epidural catheter from the skin surface to the epidural space (catheter length), and subcutaneous fat thickness (fat thickness) using CT imaging. Migration distance was calculated by subtracting needle depth from catheter length.
Results:
We analyzed 127 patients (72 males), all undergoing epidural catheter insertion in the left lateral decubitus position via a paramedian approach. The median age of the patients was 71 years. Epidural catheters were postoperatively found to substantially curve beneath the skin. Regression analysis revealed no significant influence of fat thickness on catheter length (regression coefficient 0.10, 95% confidence interval [CI]: - 0.17, 0.38). However, it indicated a positive correlation between fat thickness and needle depth (regression coefficient 0.50, 95% CI: 0.30, 0.70), and a negative correlation between fat thickness and migration distance (regression coefficient - 0.40, 95% CI: - 0.65, - 0.14).
Conclusion:
We found a negative correlation between epidural catheter migration beneath the skin and subcutaneous fat thickness. Anesthesiologists should be aware of the possibility of substantial subcutaneous curving of the catheter, especially in patients with scant subcutaneous fat.
More Related Videos
03:14Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation I: X-ray and CT