Marwan Hamiko1, Lena Gerdes1, Miriam Silaschi1
1Department of Cardiac Surgery, University Hospital Bonn, Bonn, Germany.
Background:
Severe aortic stenosis (sAS) is associated with acquired von Willebrand syndrome (AVWS) by loss of high-molecular-weight multimers (HMWM) of von Willebrand factor (VWF), potentially resulting in perioperative bleeding. Analysis of VWF multimers remains challenging. Recently, the new, rapid Hydragel 5 assay has been developed, using electrophoretic protein separation for dividing VWF-multimers into low (LMWM), intermediate (IMWM), and HMWM, the hemostatically active part of VWF. Here, we evaluated its impact on predicting blood loss in presence of AVWS after surgical aortic valve replacement (SAVR).
Methods:
We prospectively examined 52 patients (age: 68 ± 7 years; 54 % male) admitted to SAVR. They were divided in two groups (A: normal VWF, n = 28; B: abnormal VWF, n = 24, defined as VWF-activity/antigen (VWF:Ac/Ag)-ratio < 0.7 and/or HMWM loss). Blood samples and echocardiographic data were collected before, seven days and three months after SAVR. Blood loss and transfusions were recorded.
Results:
Baseline characteristics and clinical data were similar in both groups. HMWM loss was present in 38.5 % of all patients. HMWM, the VWF:Ac/Ag- and HMWM/(IMWM+LMWM)-ratios were significantly decreased preoperatively in group B but normalized after SAVR. Bleeding, re-thoracotomy and transfusion rates were comparable. HMWM loss was inversely correlated with the peak aortic gradient (Pmax) and positively with the aortic valve area (AVA), while HMWM/(IMWM+LMWM)-ratio negatively correlated with the mean aortic gradient (Pmean).
Conclusion:
HMWM and HMWM/(IMWM+LMWM)-ratio inversely correlate with severity of AS and normalize after SAVR. The Hydragel-5 assay's might be valuable for routine diagnostics to assess bleeding risk and postoperative normalization of AS and VWF abnormalities in SAVR patients.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests