Related Experiment Video
Updated: Jun 21, 2025

Author Spotlight: Efficient Image Recognition Using Directional Gradient Histogram Technique and Support Vector Machines
Published on: January 5, 2024
Experimental study on the treatment of deep miscellaneous fill foundation in Xinjiang by vibrating rod compaction
Xuejun Liu1,2, Jingchun Xue3,4, Wei Mao1,5
1College of Civil Engineering and Architecture, Xinjiang University, Urumqi, 830017, China.
Abstract:
Currently, the treatment of miscellaneous fill foundations, composed of a mixture of domestic garbage, construction solid waste, and natural soil, presents a significant challenge in urban peripheral engineering construction. This paper discusses the application of vibrating rod compaction technology for foundation treatment in Xinjiang. It evaluates the effectiveness of cross-section vibrating rod compaction equipment in reinforcing fine-grained miscellaneous fill foundations. The study analyzes the impact of construction disturbances caused by the insertion of the vibrating rod, monitoring horizontal stresses at various depths. Both laboratory and field tests show significant improvements: soil dry density increased by 8% to 18%, porosity decreased by 10% to 23%, compression modulus increased by 22% to 246%, and compression coefficient decreased by 8% to 70%. Additionally, cohesion (C) and angle of friction (ɸ) saw increases ranging from 7 to 38% and 3% to 25%, respectively. Below a depth of 3 m, cone tip resistance exceeded 10 MPa, and sidewall friction resistance increased to over 100 kPa, surpassing pre-treatment values. The standard penetration test results doubled stroke length compared to pre-treatment, indicating a substantial improvement in foundation bearing capacity. Surface wave tests before and after treatment showed a 15% increase in wave velocity, reflecting a more compact soil structure. The vibrating rod compaction method is innovative, energy-efficient, environmentally friendly, and economically beneficial, holding great potential for future miscellaneous fill treatments.
More Related Videos
10:36Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction
Published on: May 20, 2018
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
Related Concept Videos
Vibrating Concrete
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Unsoundness of Aggregate due to Volume Change
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Vebe Test
To conduct the test, concrete is placed into the slump cone. The concrete is filled in layers and...
Additives and Fillers in Concrete