Related Experiment Video
Updated: Jun 21, 2025

07:43
In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
3.0K
Is Quantitative Radiographic Measurement of Acetabular Version Reliable in Anteverted and Retroverted Hips?
Ömer Yonga1, Melih Güven2, Budak Akman1
1Department of Orthopaedics and Traumatology, Yeditepe University Hospital, Istanbul, Turkey.
Clinical Orthopaedics and Related Research
|July 12, 2024
Summary
Computed tomography (CT) scans offer more reliable acetabular version measurements than radiographs, particularly for retroverted hips. This finding is crucial for accurate diagnosis and treatment planning in hip disorders.
Area of Science:
- Orthopedic surgery
- Radiology
- Hip biomechanics
Background:
- Accurate acetabular version assessment is vital for hip function and managing hip disorders.
- Existing research shows discrepancies between radiographic and CT measurements, with limited focus on anteverted vs. retroverted hips.
Purpose of the Study:
- To compare the reliability of quantitative radiographic and CT methods for measuring acetabular version angle.
- To investigate differences in measurement reliability between radiography and CT for anteverted and retroverted hips.
- To quantify the variation in acetabular version measurements between radiographic and CT methods across hip types.
Main Methods:
- Retrospective analysis of 122 hips (from 61 patients) with both radiograph and CT scans (Jan 2020 - June 2022).
- Independent measurements by three clinicians, assessing intraobserver and interobserver reliability using Intraclass Correlation Coefficients (ICCs).
- Comparison of measurement agreement between radiography and CT, specifically for anteverted and retroverted hips, using t-tests and Bland-Altman analysis.
Main Results:
- CT measurements showed higher reliability (ICCs 0.91-0.92) than radiographic measurements (ICCs 0.78-0.87).
- Radiographic measurement reliability was moderate for anteverted hips (ICC 0.59) but poor for retroverted hips (ICC -0.41).
- Greater measurement variability was observed with radiographs in retroverted hips (6° ± 4°) compared to anteverted hips (3° ± 3°).
Conclusions:
- While radiographic measurements are acceptable, CT provides superior precision for acetabular version assessment.
- Radiographic methods exhibit a larger margin of error, especially in retroverted hips.
- CT measurement is recommended for precise acetabular version evaluation, particularly in cases of hip retroversion.

