Background:
To assess the changes in the posterior corneal surface following small incision lenticule extraction (SMILE) with different optical zones.
Methods:
In this retrospective study, 106 eyes of 106 patients who underwent SMILE were recruited 3 years after the procedure. Eyes were divided into two groups according to the size of the surgical optical zone: group A (52 eyes, ≤6.2 mm) and group B (54 eyes, ≥6.5 mm). Posterior central elevation (PCE) and 12 other points at 45°, 135°, 225° and 315° with distances of 1 mm, 2 mm and 3 mm from the centre were recorded from Pentacam.
Results:
No iatrogenic keratectasia was identified, and eyes in the two groups showed comparable visual results. The overall trend in posterior corneal elevation changes was consistent for both groups. PCE decreased significantly from 1.33 ± 2.32 to 0.75 ± 2.41 in group A (P = 0.024) and from 0.87 ± 2.61 to 0.06 ± 2.74 in group B (P = 0.003). All points in the central 2 mm region in both groups were reduced postoperatively. In the 4 mm and 6 mm corneal annulus, almost all points at 225°and 315° showed backward displacement, with the most prominent change occurring at 315° in the 6 mm annulus (P < 0.001), indicating no forward protrusion in the inferior area.
Conclusions:
No forward protrusion in the posterior corneal surface was observed 3 years after SMILE with different optical zones. Comprehensive preoperative measurements are essential for ensuring corneal stability and avoiding iatrogenic keratectasia.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy