Related Experiment Video
Updated: Jun 21, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
On the Feasibility of an LCD-Based Real-Time Converter for Ionizing Radiation Imaging
Adam Januszko1, Eugeniusz Zych2, Wiktor Piecek3
1Faculty of Security and Safety Research, General Tadeusz Kosciuszko Military University of Land Forces, Czajkowskiego 109, 51-147 Wroclaw, Poland.
Abstract:
Here we present the cascade converter (CC), which provides real-time imaging of ionizing radiation (IoR) distribution. It was designed and manufactured with the simplest architecture, utilizing liquid crystal display (LCD) technology. Based on two merged substrates with transparent electrodes, armed with functional layers, with the cell filled with nematic liquid crystal, a display-like, IoR-stimulated CC was achieved. The CC comprises low-absorbing polymer substrates (made of polyethylene terephthalate-PET) armed with a transparent ITO electrode covered with a thin semipermeable membrane of polymer (biphenylperfluorocyclobutyl: BP-PFCB) doped with functional nanoparticles (NPs) of Lu2O3:Eu. This stack was covered with a photoconductive layer of α-Se and finally with a thin polyimide (PI) layer for liquid crystal alignment. The opposite substrate was made of LCD-type glass with ITO and polyimide aligning layers. Both substrates form a cell with a twisted structure of nematic liquid crystal (TN) driven with an effective electric field Eeff. An effective electric field driving TN structure is generated with a sum of (1) a bias voltage VBIAS applied to ITO transparent electrodes and (2) the photogenerated additional voltage VXray induced between ITO and α-Se layers with a NPs-doped BP-PFCB polymer layer in-between. The IoR (here, X-ray) conversion into real imaging of the IoR distribution was achieved in the following stages: (1) conversion of IoR distribution into non-ionizing red light emitted with functional NPs, (2) transformation of red light into an electric charge distributed in a layer of the photoconductive α-Se, which is what results in the generation of distributed voltage VXray, and (3) a voltage-mediated, distributed switching of the TN structure observed with the naked eye. The presented imaging device is characterized by a simple structure and a simple manufacturing process, with the potential for use as a portable element of IoR detection and as a dosimeter.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...