Vessel diameter measurement using digital subtraction radiography.

M A Simons, R A Kruger

    Investigative Radiology
    |August 1, 1985
    PubMed
    Summary

    This study presents a new method for accurately measuring vessel diameter and cross-sectional area using digital subtraction angiography. The technique shows high linearity and accuracy, especially at higher iodine contrast concentrations.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Time resolved imaging through a highly scattering medium.

    Applied optics·2010
    Same author

    New fourier transform all-reflection interferometer.

    Applied optics·2010
    Same author

    Breast cancer in vivo: contrast enhancement with thermoacoustic CT at 434 MHz-feasibility study.

    Radiology·2000
    Same author

    Thermoacoustic CT with radio waves: a medical imaging paradigm.

    Radiology·1999
    Same author

    Response to "Comment on 'dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners' " [Med. Phys. 23, 205-220 (1996)].

    Medical physics·1996
    Same author

    World Wide Web interface to digital imaging and communication in medicine-capable image servers.

    Journal of digital imaging·1996

    Area of Science:

    • Medical Imaging
    • Vascular Measurement
    • Image Analysis

    Background:

    • Accurate measurement of vascular dimensions is crucial for diagnosing and monitoring various cardiovascular conditions.
    • Traditional methods may have limitations in precision and reproducibility, particularly with digital imaging techniques.

    Purpose of the Study:

    • To develop and validate a novel method for absolute diameter and cross-sectional area measurements from subtraction digital images.
    • To assess the accuracy and reproducibility of this method across a range of vessel sizes and contrast concentrations.

    Main Methods:

    • The method was tested using phantom vessels (1.5–5.5 mm diameter) filled with iodine contrast (23–185 mg I/ml).
    • A correction method was developed to account for non-linear video density responses to iodine concentration.

    Related Experiment Videos

  • Measurements of true versus calculated diameter were analyzed for linearity and accuracy.
  • Main Results:

    • A highly linear correlation was observed between true and calculated vessel diameters.
    • Accuracy and reproducibility ranged from +/- 1%–2% at high contrast concentrations to +/- 30% in small vessels at low concentrations.
    • The density correction method demonstrated its effect on measured diameters.

    Conclusions:

    • The described method provides a reliable approach for quantitative analysis of vessel dimensions from digital subtraction images.
    • The accuracy is dependent on vessel size and iodine contrast concentration, with improved performance at higher concentrations.
    • The developed correction technique enhances the precision of diameter measurements by addressing imaging system non-linearities.