Related Experiment Video
Updated: Jun 21, 2025

Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
CoFormerNet: A Transformer-Based Fusion Approach for Enhanced Vehicle-Infrastructure Cooperative Perception
Bin Li1, Yanan Zhao2, Huachun Tan1,3,4
1School of Transportation, Southeast University, Nanjing 211189, China.
Abstract:
Vehicle-infrastructure cooperative perception is becoming increasingly crucial for autonomous driving systems and involves leveraging infrastructure's broader spatial perspective and computational resources. This paper introduces CoFormerNet, which is a novel framework for improving cooperative perception. CoFormerNet employs a consistent structure for both vehicle and infrastructure branches, integrating the temporal aggregation module and spatial-modulated cross-attention to fuse intermediate features at two distinct stages. This design effectively handles communication delays and spatial misalignment. Experimental results using the DAIR-V2X and V2XSet datasets demonstrated that CoFormerNet significantly outperformed the existing methods, achieving state-of-the-art performance in 3D object detection.
More Related Videos
06:20Author Spotlight: Development of an Automated Camera-Based System for Real-Time Blast Overpressure Monitoring and TBI Risk Assessment in Military Training
Published on: December 6, 2024
03:31Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
Published on: December 15, 2023
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Transformers with Off-Nominal Turns Ratios
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Instrument Transformers
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...