Green method for 17-hydroxyprogesterone extraction and determination using PDMS stir bar sorptive extraction coupled
Maedeh Noori1, Zahra Talebpour2,3
1Department of Analytical Chemistry, Faculty of Chemistry, Alzahra University, Vanak, Tehran, Iran.
Abstract:
Quantifying small amounts of the 17-hydroxyprogesterone in various matrix is crucial for different purposes. In this study, a commercial polydimethylsiloxane stir bar was used to extract hormone from water and urine samples. Analysis was performed by high-performance liquid chromatography using a UV detector. The response surface methodology was used to optimize the desorption and extraction steps, with predicted optimal point relative errors of 1.25% and 6.40%, respectively. The optimized method was validated with a linear range of 1.21-1000.00 for aqueous and 2.43-2000.00 ng mL-1 for urine samples. The coefficient of determination was 0.9998 and 0.9967, and the detection limit of the proposed method was obtained to be 0.40 and 0.80 ng mL-1 for aqueous and urine samples, respectively. The recovery percentage and relative standard deviation within a day and between three days after the addition of three different concentration levels of the standard to the control sample were 87-103% and 0.4-3.6% for aqueous and 87.5-101% and 0.1-5.2% for urine samples, respectively. The results show that the proposed method can be appropriate and cost-effective for extracting and analyzing this hormone. In addition, using three different tools, the greenness of the proposed method was proven.