Clinical Application of Infrared Spectroscopy in Liver Transplantation for Rapid Assessment of Lipid Content in Liver
Audrey Coilly1, Christophe Desterke2, Slávka Kaščáková3
1Inserm, Unité 1193, Villejuif, France; Université Paris Saclay, Institut André Lwoff, Villejuif, France; AP-HP Hôpital Paul Brousse, Centre Hépatobiliaire, Villejuif, France.
Abstract:
Liver transplantation (LT) is a major treatment for patients with end-stage liver diseases. Steatosis is a significant risk factor for primary graft nonfunction and associated with poor long-term graft outcomes. Traditionally, the evaluation of steatosis is based on frozen section examination to estimate the percentage of hepatocytes containing lipid vesicles. However, this visual evaluation correlates poorly with the true lipid content. This study aimed to address the potential of infrared (IR) microspectroscopy for rapidly estimating lipid content in the context of LT and assessing its impact on survival. Clinical data were collected for >20 months from 58 patients who underwent transplantation. For each liver graft, macrovacuolar steatosis and microvesicular steatosis were evaluated through histologic examination of frozen tissue section. Triglycerides (TG) were further quantified using gas phase chromatography coupled with a flame ionization detector (GC-FID) and estimated by IR microspectroscopy. A linear relationship and significant correlation were observed between the TG measured by GC-FID and those estimated using IR microspectroscopy (R2 = 0.86). In some cases, microvesicular steatosis was related to high lipid content despite low levels of macrovacuolar steatosis. Seven patients experienced posttransplantation liver failure, including 5 deceased patients. All patients underwent transplantation with grafts containing significantly high TG levels. A concentration of 250 nmol/mg was identified as the threshold above which the risk of failure after LT significantly increased, affecting 35% of patients. Our study established a strong correlation between LT outcomes and lipid content. IR microspectroscopy proved to be a rapid and reliable approach for assessing the lipid content in clinical settings.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Applications of IR Spectroscopy: Overview