Related Experiment Video
Updated: May 2, 2026

Cellular Encapsulation in 3D Hydrogels for Tissue Engineering
Published on: October 26, 2009
Three-Dimensional DNA Hydrogel Mediated Dual-Mode Sensing Method for Quantification of Epithelial Cell Adhesion
Lu Huang1, Hanbing Huang1, Zhuomin Zhang1
1School of Chemistry, Sun Yat-sen University, Guangzhou 510006, China.
Abstract:
Monitoring changes in the expression of marker proteins in biological fluids is essential for biomarker-based disease diagnosis. Epithelial cell adhesion molecule (EpCAM) has been identified as a broad-spectrum biomarker for various chronic diseases and as a therapeutic target. However, the development of simple and reliable methods for quantifying EpCAM changes in biological fluids faces challenges due to the variability of its expression across different diseases, the presence of soluble forms, and matrix effects. In this paper, a surface-enhanced Raman scattering (SERS)-fluorescence (FL) dual-mode sensing method was established for quantification of trace EpCAM in biological fluids based on bimetallic Au@Ag nanoparticles and nitrogen-doped quantum dots encapsulated DNA hydrogel hybrid with graphene oxide (Au@Ag-NQDs/GO). The DNA hydrogel was constructed based on three-dimensional (3D) structure DNA-mediated strategy using an aptamer DNA (AptDNA) linker. The interaction of the AptDNA with EpCAM triggered the disassembly of the DNA hydrogel. Consequently, the release of Au@Ag nanoparticles induced an "on-off" switch in the SERS signal while the weakened FL quenching effect in Au@Ag-NQDs/GO system achieved "off-on" switch of FL signal, enabling the simultaneous SERS-FL quantification of EpCAM. The established dual-mode method exhibited outstanding sensitivity and stability in quantifying EpCAM in the range of 0.5-60.0 pg/mL, with the limits of detection (LODs) of SERS and FL as 0.17 and 0.35 pg/mL, respectively. When applied for real sample analysis, the method showed satisfactory specificity and recoveries in cancer cells lysate, serum, and urine samples with RSDs of 2.8-6.3%, 4.0-6.3%, and 2.8-5.7%, respectively. The developed SERS-FL sensing method offered a sensitive, reliable, and practical quantification strategy for trace EpCAM in diverse biological fluid samples, which would benefit the early diagnosis of disease and further health management.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Three-Dimensional Microscopy in Microbiology

