Intraindividual Comparison of Different Methods for Automated BPE Assessment at Breast MRI: A Call for
Gustav Müller-Franzes1, Firas Khader1, Soroosh Tayebi Arasteh1
1From the Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Pauwelsstr 30, 52074 Aachen, Germany (G.M.F., F.K., S.T.A., L.H., M.B., T.H., T.L., S.N., C.K., D.T.); National Center for Tumor Diseases, Heidelberg University Hospital, Heidelberg, Germany (J.N.K.); Department of Medical Oncology, Heidelberg University Hospital, Heidelberg, Germany (J.N.K.); Else Kroener Fresenius Center for Digital Health, Technical University Dresden, Dresden, Germany (J.N.K.); and Department of Medicine I, University Hospital Dresden, Dresden, Germany (J.N.K.).
Abstract:
Background The level of background parenchymal enhancement (BPE) at breast MRI provides predictive and prognostic information and can have diagnostic implications. However, there is a lack of standardization regarding BPE assessment. Purpose To investigate how well results of quantitative BPE assessment methods correlate among themselves and with assessments made by radiologists experienced in breast MRI. Materials and Methods In this pseudoprospective analysis of 5773 breast MRI examinations from 3207 patients (mean age, 60 years ± 10 [SD]), the level of BPE was prospectively categorized according to the Breast Imaging Reporting and Data System by radiologists experienced in breast MRI. For automated extraction of BPE, fibroglandular tissue (FGT) was segmented in an automated pipeline. Four different published methods for automated quantitative BPE extractions were used: two methods (A and B) based on enhancement intensity and two methods (C and D) based on the volume of enhanced FGT. The results from all methods were correlated, and agreement was investigated in comparison with the respective radiologist-based categorization. For surrogate validation of BPE assessment, how accurately the methods distinguished premenopausal women with (n = 50) versus without (n = 896) antihormonal treatment was determined. Results Intensity-based methods (A and B) exhibited a correlation with radiologist-based categorization of 0.56 ± 0.01 and 0.55 ± 0.01, respectively, and volume-based methods (C and D) had a correlation of 0.52 ± 0.01 and 0.50 ± 0.01 (P < .001). There were notable correlation differences (P < .001) between the BPE determined with the four methods. Among the four quantitation methods, method D offered the highest accuracy for distinguishing women with versus without antihormonal therapy (P = .01). Conclusion Results of different methods for quantitative BPE assessment agree only moderately among themselves or with visual categories reported by experienced radiologists; intensity-based methods correlate more closely with radiologists' ratings than volume-based methods. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Mann in this issue.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: